2-conductor through terminal block; 2.5 mm²; with test option; same profile as 2-conductor disconnect terminal block; side and center marking; for din-rail 35 x 15 and 35 x 7.5; push-in cage clamp®; 2,50 mm²; blue

Ratings per: IEC/EN 60947-7-1;Tesiune nominala (III/3): 400; VTensiune nominala de supratensiune (III/3): 6; kVCurent nominal: 16; ALegend (ratings): (III / 3) â?? Overvoltage category III / Pollution degree 3;Tensiune nominala ...

15.09 Ron
Double-deck terminal block; through/through terminal block; with end plate; l/n; without marker carrier; blue conductor entry upper deck; for din-rail 35 x 15 and 35 x 7.5; 2.5 mm²; push-in cage clamp®; 2,50 mm²; gray

Ratings per: IEC/EN 60947-7-1;Tesiune nominala (III/3): 800; VTensiune nominala de supratensiune (III/3): 8; kVCurent nominal: 24; ALegend (ratings): (III / 3) â?? Overvoltage category III / Pollution degree 3;Tensiune nominala ...

13.10 Ron
Double-deck terminal block; through/through terminal block; with end plate; n/l; without marker carrier; blue conductor entry lower deck; for din-rail 35 x 15 and 35 x 7.5; 1 mm²; push-in cage clamp®; 1,00 mm²; gray

Ratings per: IEC/EN 60947-7-1;Tesiune nominala (III/3): 800; VTensiune nominala de supratensiune (III/3): 8; kVCurent nominal: 13,5; ACurent nominal 2: 16; ALegend (ratings): (III / 3) â?? Overvoltage category III / ...

12.46 Ron
Double-deck terminal block; through/through terminal block; with end plate; l/n; without marker carrier; blue conductor entry upper deck; for din-rail 35 x 15 and 35 x 7.5; 1 mm²; push-in cage clamp®; 1,00 mm²; gray

Ratings per: IEC/EN 60947-7-1;Tesiune nominala (III/3): 800; VTensiune nominala de supratensiune (III/3): 8; kVCurent nominal: 13,5; ACurent nominal 2: 16; ALegend (ratings): (III / 3) â?? Overvoltage category III / ...

12.46 Ron
Double-deck terminal block; through/through terminal block; with end plate; n/l; without marker carrier; blue conductor entry lower deck; for din-rail 35 x 15 and 35 x 7.5; 2.5 mm²; push-in cage clamp®; 2,50 mm²; gray

Ratings per: IEC/EN 60947-7-1;Tesiune nominala (III/3): 800; VTensiune nominala de supratensiune (III/3): 8; kVCurent nominal: 24; ALegend (ratings): (III / 3) â?? Overvoltage category III / Pollution degree 3;Tensiune nominala ...

13.10 Ron
Double-deck terminal block; through/through terminal block; with end plate; n/l; with marker carrier; blue conductor entry lower deck; for din-rail 35 x 15 and 35 x 7.5; 2.5 mm²; push-in cage clamp®; 2,50 mm²; gray

Ratings per: IEC/EN 60947-7-1;Tesiune nominala (III/3): 800; VTensiune nominala de supratensiune (III/3): 8; kVCurent nominal: 24; ALegend (ratings): (III / 3) â?? Overvoltage category III / Pollution degree 3;Tensiune nominala ...

13.74 Ron
Double-deck terminal block; through/through terminal block; with end plate; l/n; with marker carrier; blue conductor entry upper deck; for din-rail 35 x 15 and 35 x 7.5; 2.5 mm²; push-in cage clamp®; 2,50 mm²; gray

Ratings per: IEC/EN 60947-7-1;Tesiune nominala (III/3): 800; VTensiune nominala de supratensiune (III/3): 8; kVCurent nominal: 24; ALegend (ratings): (III / 3) â?? Overvoltage category III / Pollution degree 3;Tensiune nominala ...

13.74 Ron
Double-deck terminal block; 4-conductor through terminal block; n; suitable for ex i applications; internal commoning; conductor entry with violet marking; for din-rail 35 x 15 and 35 x 7.5; 2.5 mm²; cage clamp®; 2,50 mm²; blue

Ratings per: IEC/EN 60947-7-1;Tesiune nominala (III/3): 500; VTensiune nominala de supratensiune (III/3): 6; kVCurent nominal: 24; ALegend (ratings): (III / 3) â?? Overvoltage category III / Pollution degree 3;Tehnologie conexiune: ...

14.56 Ron
Double-deck terminal block; through/through terminal block; with end plate; l/n; with marker carrier; blue conductor entry upper deck; for din-rail 35 x 15 and 35 x 7.5; 1 mm²; push-in cage clamp®; 1,00 mm²; gray

Ratings per: IEC/EN 60947-7-1;Tesiune nominala (III/3): 800; VTensiune nominala de supratensiune (III/3): 8; kVCurent nominal: 13,5; ACurent nominal 2: 16; ALegend (ratings): (III / 3) â?? Overvoltage category III / ...

13.33 Ron
Double-deck terminal block; through/through terminal block; with end plate; n/l; with marker carrier; blue conductor entry lower deck; for din-rail 35 x 15 and 35 x 7.5; 1 mm²; push-in cage clamp®; 1,00 mm²; gray

Ratings per: IEC/EN 60947-7-1;Tesiune nominala (III/3): 800; VTensiune nominala de supratensiune (III/3): 8; kVCurent nominal: 13,5; ACurent nominal 2: 16; ALegend (ratings): (III / 3) â?? Overvoltage category III / ...

13.33 Ron
Double-deck terminal block; 4-conductor through terminal block; n; suitable for ex i applications; internal commoning; conductor entry with violet marking; for din-rail 35 x 15 and 35 x 7.5; 1.5 mm²; cage clamp®; 1,50 mm²; blue

Ratings per: IEC/EN 60947-7-1;Tesiune nominala (III/3): 500; VTensiune nominala de supratensiune (III/3): 6; kVCurent nominal: 18; ALegend (ratings): (III / 3) â?? Overvoltage category III / Pollution degree 3;Tehnologie conexiune: ...

23.39 Ron
Double-deck terminal block; through/through terminal block; n/l; without marker carrier; suitable for ex e ii applications; blue conductor entry lower deck; for din-rail 35 x 15 and 35 x 7.5; 2.5 mm²; push-in cage clamp®; 2,50 mm²; gray

Ratings per: IEC/EN 60947-7-1;Tesiune nominala (III/3): 500; VTensiune nominala de supratensiune (III/3): 6; kVCurent nominal: 24; ACurent nominal 2: 28; ALegend (ratings): (III / 3) â?? Overvoltage category III / ...

11.05 Ron
Double-deck terminal block; through/through terminal block; l/n; without marker carrier; suitable for ex e ii applications; blue conductor entry upper deck; for din-rail 35 x 15 and 35 x 7.5; 2.5 mm²; push-in cage clamp®; 2,50 mm²; gray

Ratings per: IEC/EN 60947-7-1;Tesiune nominala (III/3): 500; VTensiune nominala de supratensiune (III/3): 6; kVCurent nominal: 24; ACurent nominal 2: 28; ALegend (ratings): (III / 3) â?? Overvoltage category III / ...

11.11 Ron
Triple-deck terminal block; through/through/through terminal block; l/l/n; without marker carrier; suitable for ex e ii applications; blue conductor entry upper deck; for din-rail 35 x 15 and 35 x 7.5; 2.5 mm²; push-in cage clamp®; 2,50 mm²; gray

Ratings per: IEC/EN 60947-7-1;Tesiune nominala (III/3): 500; VTensiune nominala de supratensiune (III/3): 6; kVCurent nominal: 24; ACurent nominal 2: 28; ALegend (ratings): (III / 3) â?? Overvoltage category III / ...

18.36 Ron
Triple-deck terminal block; through/through/through terminal block; l/l/n; with marker carrier; suitable for ex e ii applications; blue conductor entry upper deck; for din-rail 35 x 15 and 35 x 7.5; 2.5 mm²; push-in cage clamp®; 2,50 mm²; gray

Ratings per: IEC/EN 60947-7-1;Tesiune nominala (III/3): 500; VTensiune nominala de supratensiune (III/3): 6; kVCurent nominal: 24; ACurent nominal 2: 28; ALegend (ratings): (III / 3) â?? Overvoltage category III / ...

19.30 Ron
Double-deck terminal block; through/through terminal block; n/l; with marker carrier; suitable for ex e ii applications; blue conductor entry lower deck; for din-rail 35 x 15 and 35 x 7.5; 2.5 mm²; push-in cage clamp®; 2,50 mm²; gray

Ratings per: IEC/EN 60947-7-1;Tesiune nominala (III/3): 500; VTensiune nominala de supratensiune (III/3): 6; kVCurent nominal: 24; ACurent nominal 2: 28; ALegend (ratings): (III / 3) â?? Overvoltage category III / ...

11.75 Ron
Double-deck terminal block; through/through terminal block; l/n; with marker carrier; suitable for ex e ii applications; blue conductor entry upper deck; for din-rail 35 x 15 and 35 x 7.5; 2.5 mm²; push-in cage clamp®; 2,50 mm²; gray

Ratings per: IEC/EN 60947-7-1;Tesiune nominala (III/3): 500; VTensiune nominala de supratensiune (III/3): 6; kVCurent nominal: 24; ACurent nominal 2: 28; ALegend (ratings): (III / 3) â?? Overvoltage category III / ...

11.75 Ron
Double-deck terminal block; through/through terminal block; l/n; without marker carrier; suitable for ex e ii applications; blue conductor entry upper deck; for din-rail 35 x 15 and 35 x 7.5; 2.5 mm²; push-in cage clamp®; 2,50 mm²; gray

Ratings per: IEC/EN 60947-7-1;Tesiune nominala (III/3): 800; VTensiune nominala de supratensiune (III/3): 8; kVCurent nominal: 24; ACurent nominal 2: 28; ALegend (ratings): (III / 3) â?? Overvoltage category III / ...

13.33 Ron
Double-deck terminal block; through/through terminal block; n/l; without marker carrier; suitable for ex e ii applications; blue conductor entry lower deck; for din-rail 35 x 15 and 35 x 7.5; 2.5 mm²; push-in cage clamp®; 2,50 mm²; gray

Ratings per: IEC/EN 60947-7-1;Tesiune nominala (III/3): 800; VTensiune nominala de supratensiune (III/3): 8; kVCurent nominal: 24; ACurent nominal 2: 28; ALegend (ratings): (III / 3) â?? Overvoltage category III / ...

13.33 Ron
2-conductor through terminal block; 2.5 mm²; with test option; with additional jumper position; same profile as 2-conductor disconnect terminal block; side and center marking; for din-rail 35 x 15 and 35 x 7.5; push-in cage clamp®; 2,50 mm²; blue

Ratings per: IEC/EN 60947-7-1;Tesiune nominala (III/3): 400; VTensiune nominala de supratensiune (III/3): 6; kVCurent nominal: 16; ALegend (ratings): (III / 3) â?? Overvoltage category III / Pollution degree 3;Tensiune nominala ...

16.14 Ron


Nu ati gasit ce cautati?
Completati o cerere de produs sau serviciu si firmele inscrise pe site va vor face oferte personalizate.

Etichete
Tapet living | Amenajari interioare apartamente | Plasa antigrindina | Coltare extensibile cluj | Coltare living moderne | Compartimentare sifonier | Confectionare ceas de carton | Constructii metalice | Contor electric pret | Copertine retractabile |

Magazine online

SC Criber NET SRL
SC Criber NET SRL
danco prest
danco prest
mobilier comandaComert Industrial SRL
Comert Industrial SRL
Despre noi | Contact | Publicitate pe site | Pachete de servicii
Privacy....