bf95 t4

Ati cautat bf95 t4

Contactor tripolar, curent lucru (ac3) = 32a, dc bobina, 125vdc

Releu termic protectie motor, Fara eroare lipsa faza,fazare. tripolar,resetare manuala. Montaj direct pe BF95 - BF150 CONTACTORS, 60...82A ...

997.25 Ron
Contactor tripolar, curent lucru (ac3) = 32a, dc bobina, 220vdc

Releu termic protectie motor, Fara eroare lipsa faza,fazare. tripolar,resetare manuala. Montaj direct pe BF95 - BF150 CONTACTORS, 70...95A ...

997.25 Ron
Contactor tripolar, curent lucru (ac3) = 32a, dc bobina low consumption, 24vdc

Releu termic protectie motor, Fara eroare lipsa faza,fazare. tripolar,resetare manuala. Montaj direct pe BF95 - BF150 CONTACTORS, 90...110A ...

977.31 Ron
Contactor tripolar, curent lucru (ac3) = 40a, ac bobina 50/60hz, 230vac

Releu termic protectie motor, eroare lipsa faza, fazare . tripolar,resetare manuala. Montaj direct pe BF95 - BF110 CONTACTORS, 90…110A ...

791.52 Ron
Contactor tripolar, curent lucru (ac3) = 40a, ac bobina 60hz, 220vac

Releu termic protectie motor, eroare lipsa faza, fazare . tripolar,resetare manuala. Montaj direct pe BF95 - BF110 CONTACTORS, 60…82A ...

791.52 Ron
Contactor tripolar, curent lucru (ac3) = 40a, ac bobina 60hz, 230vac

Releu termic protectie motor, eroare lipsa faza, fazare . tripolar,resetare manuala. Montaj direct pe BF95 - BF110 CONTACTORS, 70…95A ...

791.52 Ron
Contactor tripolar, curent lucru (ac3) = 40a, ac bobina 60hz, 460vac

Releu termic protectie motor, eroare lipsa faza, fazare . tripolar, resetare automata. Montaj direct pe BF95 - BF110 CONTACTORS, 90…110A ...

791.52 Ron
Contactor tripolar, curent lucru (ac3) = 50a, ac bobina 50/60hz, 24vac

Releu termic protectie motor, eroare lipsa faza, fazare . tripolar, resetare automata. Montaj direct pe BF95 - BF110 CONTACTORS, 60…82A ...

973.04 Ron
Contactor tripolar, curent lucru (ac3) = 50a, ac bobina 50/60hz, 48vac

Releu termic protectie motor, eroare lipsa faza, fazare . tripolar, resetare automata. Montaj direct pe BF95 - BF110 CONTACTORS, 70…95A ...

973.04 Ron
Contactor tripolar, curent lucru (ac3) = 50a, ac bobina 50/60hz, 110vac

Releu termic protectie motor, Fara eroare lipsa faza,fazare. tripolar,resetare manuala. Montaj direct pe BF95 - BF110 CONTACTORS, 90…110A ...

973.04 Ron
Contactor tripolar, curent lucru (ac3) = 50a, ac bobina 60hz, 48vac

Releu termic protectie motor, Fara eroare lipsa faza,fazare. tripolar,resetare manuala. Montaj direct pe BF95 - BF110 CONTACTORS, 60…82A ...

973.04 Ron
Contactor tripolar, curent lucru (ac3) = 50a, ac bobina 60hz, 120vac

Releu termic protectie motor, Fara eroare lipsa faza,fazare. tripolar,resetare manuala. Montaj direct pe BF95 - BF110 CONTACTORS, 70…95A ...

973.04 Ron


Nu ati gasit ce cautati?
Completati o cerere de produs sau serviciu si firmele inscrise pe site va vor face oferte personalizate.

Etichete
Amenajari baie gresie faianta | Balansoar din lemn | Balansoar obi | Balustrada lemn | Balustrade din fier forjat | Scaune praktiker | Stuco venetian | Cornier pret | Draperii moderne | Auchan electrocasnice |

Magazine online

Conan
Conan
SC Criber NET SRL
SC Criber NET SRL
danco prest
danco prest
mobilier comanda
Despre noi | Contact | Publicitate pe site | Pachete de servicii
Privacy....